EQUIPO DE ENCENDIDO Y REGULACIÓN PARA TIRISTORES

CONTROLE SUS INSTALACIONES DE CONVERTIDORES DE CORRIENTE CON REOTRON MDZ

Los equipos de encendido y regulación MDZ están concebidos para regular semiconductores de potencia externos e instalaciones de convertidores de corriente externas, por ejemplo, en la galvanotecnia. Incluyen un regulador para regulación de corriente y tensión respectivamente.

En el modo de funcionamiento de regulación de tensión, la tensión de salida especificada por el valor teórico se mantiene constante gracias a un circuito de regulación interno. De este modo, las variaciones de carga o las oscilaciones de tensión de red no alteran la tensión de salida.

  • REOTRON MDZ

    Thyristor firing & control unit: Cabinet mounting version (IP 20)

    REOTRON mDZ
    • Tensión de entrada: 3 x 400 V +6 % - 10%
    • Tensión de salida: 3x0...3xUe V

    The firing & control units MDZ have been designed for the control of current converter installations, e.g. in electroplating plants. They contain one controller each for current and vol-tage control. In the voltage control mode, the output voltage is kept constant at a predefined setpoint value by the internal control circuit. Therefore, changes in the load or in the mains supply have no effect on the output voltage.


    When operated in the current control mode, the output current is compared with the setpoint, and corrected accordingly. Hereby, the output voltage can increase to its maximum value. If the preset limits (Imax or Vmax) are exceeded, this is signalled by LEDs.


    If both control modes are used together, the controller with the lower setpoint always has priority. For example, with voltage control and subordinated current control, this means that the voltage controller is in command as long as the permissible current value is not exceeded. As soon as the current limit is reached, the current controller takes over.If the unit is to be operated purely as a voltage or current controller, the respective other setpoint must be set to the 10 VDC reference value.


    Intended for installation in a control cabinet, the unit is mounted in a compact aluminium hou-sing. All electrical connections are made via plug-in screw terminals. The controls for adjus-ting the operating parameters are accessible on the front panel.